The output is dependent on the components of design with a entire assortment of different resources for differing applications and temperature ranges, which is way outside of the scope of this write-up. For instance a standard low expense thermocouple would be a kind K which is produced from Nickel and Chromium and creates an output of 41μV/oC becoming a magnetic substance can trigger some difficulties with linearity at temperatures above 350ºC this is yet again exterior the scope of this post. For greater temperature applications Sort B, R or S can be used up to 1600ºC these thermocouples are substantially a lot more pricey being made from Platinum / Rhodium with an output of 10μVºC. kalibrering

The downside of thermocouples is they can't be connected to normal copper cable as one more junction of dissimilar metals would be created in the connecting head which would also create a millivolt sign and hence an mistake. So a cable with the identical qualities as the thermocouple need to be employed to link back to the temperature controller this is referred to as compensating cable. The connection at the instrument terminals with the comp cable can generate a modest millivolt prospective which needs to be compensated for this is often referred to as the cold junction temperature.

PRT Theory

The temperature instrument or transmitter provides a low voltage to the platinum resistance sensor which causes a current to stream generating an electrical circuit.

By ohms legislation the voltage fall in the circuit and therefore the existing flow is proportional to the resistance in the circuit. As the temperature increases the resistance of the PT100 raises:- this is a good temperature coefficient. The problem with the two wire configuration is the instrument reads the resistance of the connecting cable as effectively as the temperature sensor.

There are some easy techniques to circumnavigate this difficulty has detailed beneath in the connection particulars for the 3 & 4 wire programs.

Connections for two wire devices

Red Wire

White Wire

In this circuit the resistance is three + one hundred + three Ω = 106 Ω

Connections for three wire devices

Purple Wire

Purple Wire

White Wire

In this circuit the temperature instrument actions the resistance in between the purple and white wires, it also measures the resistance amongst the two red wires.

The temperature controller will subtract the resistance amongst the red wires from the resistance between the crimson and white wires to compensate for the resistance in the cable. The instrument assumes that the resistance in all the wires are equal to every other.

Connections for 4 wire devices

Crimson Wire

Red Wire

White Wire

White Wire

The 4 wire connections are generally linked to the 4 arms of a wheatstone bridge kind circuit so that the resistances terminate every single other out.

In our view the value of set up of a lengthy cable operate is increased than setting up a four-20mA two wire temperature transmitter.

A two wire 4-20mA temperature transmitter gives precision sign transfer above an effective length up to one thousand metres absent. We would recommend the TT100 4-20mA Temperature Transmitter paired with a BC7635 Controller as a suited alternative.

Platinum Resistance Thermometer Desk


•Temperature | Resistance

•-100ºC | 60.26Ω

•-50ºC | 80.31Ω

•-20ºC | 92.16Ω

•0ºC | one hundred.00Ω

•20ºC | 107.29Ω

•25ºC | 109.73Ω

•30ºC | 107.67Ω

•50ºC | 119.40Ω

•75ºC | 128.98Ω

•100ºC | 138.51Ω

•150ºC | 157.33Ω