Uninterruptible Power Supplies Installation Options

De BISAWiki

Edição feita às 19h33min de 29 de maio de 2013 por Elina744 (disc | contribs)
(dif) ← Versão anterior | ver versão atual (dif) | Versão posterior → (dif)

As the description implies this represents a single uninterruptible power provide installation comprising of the UPS and battery exactly where the battery can be internal or external and consist of single or multiple strings. A number of strings can increase the autonomy and also supply greater security of load in the occasion of a utility mains failure.

It ought to be noted that when the load has been transferred to the upkeep bypass mode it would be unpro...

Single UPS installation

As the description implies this represents a single uninterruptible power supply installation comprising of the UPS and battery exactly where the battery can be internal or external and consist of single or several strings. Several strings can improve the autonomy and also offer higher safety of load in the occasion of a utility mains failure.

It must be noted that when the load has been transferred to the upkeep bypass mode it would be unprotected in the occasion of a utility mains failure.

Hot Standby UPS Installation

This installation makes use of two UPS modules alarm systems security, referred to as a UPS Program one particular (A) is directly coupled to the load home monitored security system, the output of the second (B) supplies the reserve input of A. For that reason if UPS A inverter fails the load is switched to the inverter output of UPS B and is nonetheless protected in the event of a utility mains failure. Equally either UPS can be switched to the maintenance bypass condition with no loss of protection to the load in the event of a utility mains failure. This is employed when either the UPS or Generator power protection program are serviced as portion of a normal maintenance regime.

Parallel Redundant UPS Installation- N+1

This installation can consist of up to eight modules and can be comprehensive with a static switch module. This kind of installation is created to make certain that when fully loaded there is enough capacity to take away 1 module from service either for repair or upkeep without having altering the integrity of the program. The added benefit is that the technique with assistance an overload scenario exactly where redundancy is lost.

Parallel UPS Installation- Sharing the vital load

This installation consists of two or far more, usually up to a maximum of eight modules dependent upon UPS manufacturer, to assistance the load. The quantity of modules is made to support the load and can be a hassle-free technique of installation where 1 module on its personal could be also massive to physically match in the desired place. Also, as in the parallel redundant installation, supplying the quantity of modules has not exceeded the manufacturer's design needs modules may be added as the web site load increases.

It should be noted that it is not attainable to parallel all sorts of UPS systems and that the person modules require to be the same make, module and capacity and will call for extra circuitry to supply the parallel handle.

Disaster Preventative installation

This normally consists of a substantial UPS program backed by a diesel Generator

Bear in mind, PowerContinuity Means Organization Continuity. To ensure that failure is not an option, often take into consideration: is your power protected? If not, what measures ought to I take to make sure that it is?

For additional data with regards to uninterruptible energy supplies, diesel generators, energy protection or any other related energy query, please visit our web site at and/or give us a contact on 0845 055 8455. Call or pay a visit to us now and locate your answer. Your energy we shield. Power Continuity.